Figure 1. Simple fixed orifice (a) and variable orifice (b) flow controls.

Figure 2. Flow regulator adjusts to variations in inlet and output pressures.

Figure 3. Bypass flow regulator returns excess flow from pump to tank.

Figure 4. Demand-compensated flow control bypasses full pump output to tank during idle portion of work cycle.

Figure 5. Pressure-compensated, variable flow-control valve adjusts to varying inlet and load pressures.

Figure 6. Pressure-and temperature-compensated, variable flowcontrol valve adjusts orifice size to offset changes in fluid viscosity.

Figure 7. Priority valve supplies fluid at a set rate to a primary circuit.

Figure 8. Deceleration valve slows load by being gradually closed by action of cam mounted on cylinder load.


The purpose of flow control in a hydraulic system is to regulate speed. Flow rate also determines rate of energy transfer at any given pressure. The two are related in that the actuator force multiplied by the distance through which it moves (stroke) equals the work done on the load. The energy transferred must also equal the work done. Actuator speed determines the rate of energy transfer (i.e., horsepower), and speed is thus a function of flow rate.

Directional control, on the other hand, does not deal primarily with energy control, but rather with directing the energy transfer system to the proper place in the system at the proper time. Directional control valves can be thought of as fluid switches that make the desired " contacts." That is, they direct the high-energy input stream to the actuator inlet and provide a return path for the lower-energy oil.

It is of little consequence to control the energy transfer of the system through pressure and flow controls if the flow stream does not arrive at the right place at the right time. Thus, a secondary function of directional control devices might be defined as the timing of cycle events. Because fluid flow often can be throttled in directional-control valves, some measure of flow rate or pressure control can also be achieved with them.

Types of flow measurement
Controlling flow of a fluid-power system does not necessarily mean regulating volume per unit of time from a valve. Flow rate can be specified three different ways, so it is important to be aware of how flow is to be specified or measured:

Volumetric flow rate, Qv, expressed in units of in.3/sec or min — or cc/sec or cc/min in SI metric measure — is used to calculate the linear speeds of piston rods or rotational speeds of motor shafts.

Weight flow rate, Qw, expressed in units of lb/sec or lb/min, is used to calculate power using English units of measure.

Mass flow rate, Qg, expressed in units of slugs/sec or slugs/min for English measure — or kg/sec or kg/min in SI metric measure — is used to calculate inertia forces during periods of acceleration and deceleration.

Because they control the quantity of fluid that flows through the valve per unit of time, the same control valves are used for all three types of flow rates.

Control of flow rate with valves

There are eight types of flow-control valves:

Orifices — A simple orifice in the line, Figure 1(a), is the most elementary method for controlling flow. (Note that this is also a basic pressure control device.) When used to control flow, the orifice is placed in series with the pump. An orifice can be a drilled hole in a fitting, in which case it is fixed; or it may be a calibrated needle valve, in which case it functions as a variable orifice, Figure 1(b). Both types are non-compensated flow-control devices.

Flow regulators — This device, Figure 2, which is slightly more sophisticated than a fixed orifice, consists of an orifice that senses flow rate as a pressure drop across the orifice; a compensating piston adjusts to variations in inlet and outlet pressures. This compensating ability provides closer control of flow rate under varying pressure conditions. Control accuracy may be 5%, possibly less with specially calibrated valves that operate around a given flow-rate point.

Bypass flow regulators — In this flow regulator, flow in excess of set flow rate returns to reservoir through a bypass port, Figure 3. Flow rate is controlled by throttling fluid across a variable orifice regulated by the compensator piston. The bypass flow regulator is more efficient than a standard flow regulator.

Demand-compensated flow controls — Flow controls can also bypass excess system flow to a secondary circuit, Figure 4. Fluid is routed at a controlled flow rate to the primary circuit, and bypass fluid can be used for work functions in secondary circuits without affecting the primary one. There must be flow to the primary circuit for this type of valve to function — if the primary circuit is blocked, the valve will cut off flow to the secondary circuit.

Pressure-compensated, variable flow valves — This flow control is equipped with an adjustable variable orifice placed in series with a compensator. The compensator automatically adjusts to varying inlet and load pressures, maintaining an essentially constant flow rate under these operating conditions to accuracies of 3 to 5%, Figure 5. Pressure-compensated, variable flow-control valves are available with integral reverse-flow check valves (which allow fluid to flow unrestricted in the opposite direction) and integral overload relief valves (which route fluid to tank when a maximum pressure is exceeded).

Pressure-and temperaturecompensated, variable flow valves — Because the viscosity of hydraulic oil varies with temperature (as do the clearances between a valve's moving parts), output of a flow-control valve may tend to drift with temperature changes. To offset the effects of such temperature variations, temperature compensators adjust the control orifice openings to correct the effects of viscosity changes caused by temperature fluctuations of the fluid, Figure 6. This is done in combination with adjustments to the control orifice for pressure changes as well.

Priority valves — A priority valve, Figure 7, is essentially a flow-control valve that supplies fluid at a set flow rate to the primary circuit, thus functioning as a pressure-compensated flow-control valve. Flow in excess of that required by the primary-circuit bypasses to a secondary-circuit at a pressure somewhat below that of the primary circuit. Should inlet or load pressure (or both) vary, the primary circuit has priority over the secondary — as far as supplying the design flow rate is concerned.

Deceleration valves — A deceleration valve, Figure 8, is a modified 2-way, spring-offset, cam actuated valve used for decelerating a load driven by a cylinder. A cam attached to the cylinder rod or load closes the valve gradually. This provides a variable orifice that gradually increases backpressure in the cylinder as the valve closes. Some deceleration valves are pressure-compensated.

Other flow controls
Flow dividers — A flow-divider valve is a form of pressure-compensated flow-control valve that receives one input flow and splits it into two output flows. The valve can deliver equal flows in each stream or, if necessary, a predetermined ratio of flows.

Like all pressure-and flow-control devices, flow dividers operate over a narrow bandwidth rather than at one set point. Thus, flow variations in the secondary branches are likely. Therefore, precise actuator synchronization cannot be achieved with a flowdivider valve alone. Flow dividers can also be used in meter-out circuit configurations or cascaded — connected in series to control multiple actuator circuits.

Rotary flow dividers — Another technique for dividing one input flow into proportional, multiple-branch output flows is with a rotary flow divider. It consists of several hydraulic motors connected together mechanically by a common shaft. One input fluid stream is split into as many output streams as there are motor sections in the flow divider. Because all motor sections turn at the same speed, output stream flow rates are proportional and equal to the sum of displacements of all the motor sections. Rotary flow dividers can usually handle larger flows than flow divider valves.

The pressure drop across each motor section is relatively small because no energy is delivered to an external load, as is the usual case with a hydraulic motor. However, designers should be aware of pressure intensification generated by a rotary flow divider. If, for any reason, load pressure in one or more branches drops to some lower level or to zero, full differential pressure will be applied across the motor section in each particular branch. The sections thus pressurized will act as hydraulic motors and drive the remaining section(s) as pump(s). This results in higher (intensified) pressure in these circuits' branches. When specifying rotary flow dividers, system designers must be careful to minimize the potential for pressure intensification. A pressure relief valve should be placed in any actuator fluid line where this condition may occur. Rotary flow dividers can also integrate multiple branch return flows into a single return flow.

Proportional flow-control valves
Proportional flow-control valves combine state-of-the-art hydraulic valve actuation with modern, sophisticated electronic control. These valves help simplify hydraulic circuitry by reducing the number of components a system may require while at the same time, substantially increasing system accuracy and efficiency.

An electronically controlled, proportional flow-control valve modulates fluid flow in proportion to the input current it receives. The valves can easily control cylinders or smaller hydraulic motors in applications that require precise speed control or controlled acceleration or deceleration. Most proportional flow-control valves are pressure-compensated to minimize flow variations caused by changes in inlet or outlet pressure.

An electrohydraulic proportional valve consists of three main elements:

  • a pilot or proportional solenoid
  • a metering area (where the valve spool is located), and
  • an electronic position-feedback device, often an LVDT (linear variable differential transformer).

Valve operation begins when it receives a signal from an outside controlling device such as a computer, programmable logic controller (PLC), traditional logic relay, or potentiometer. The control device delivers analog electrical signals to the valve driver card, which, in turn, sends a current signal to the solenoid on the valve.

The electromechanical force on the spool causes it to shift, gradually opening a flow path from the pump to the actuator port. The greater the command input signal, the greater the current to the valve solenoid, and, thus, the higher the flow from the valve. The important feature of this proportional valve is that all elements are proportional; thus, any change in input current changes force signals proportionately as well as the distance the valve spool will shift, the size of the flow path, the amount of fluid flowing through the valve, and finally the speed at which the actuator moves.

As the spool shifts, its motion is detected and monitored very accurately by an LVDT or other type of position-feedback transducer. This signal is fed back to the driver card where it is continuously compared with the input signals from the controller. If the two differ, the driver adjusts spool position until the two signals match.

Pressure-compensated proportional flow-control valves are 2-port valves in which the main control orifice is adjusted electronically. Similar to conventional pressurecompensated flow-control valves, a pressure-compensated proportional flow-control valve maintains constant flow output by keeping the pressure drop constant across the main control orifice. The proportional valve, however, is different in that the control orifice is modified to work in conjunction with a stroke-controlled solenoid.

Which flow control to use for an application

Application Type of flow-control valve
Load on the actuator and supply pressure both are constant: ±5% accuracy Non-compensated, fixed or variable flow control, depending on application
Load on the actuator, supply pressure, or both undergo changes: ±3-5% accuracy Pressure-compensated, fixed or variable flow control, depending on application
Load on the actuator, supply pressure, or both change, and fluid temperature varies ±30° F (±17° C): ±3-5% accuracy Pressure-and temperature-compensated, fixed or variable flow control
The best type of flow control valve to use depends on the design parameters of the application. Above are general guidelines based on common application characteristics.

For more information on flow control valves, including illustrations of different types of flow controls, visit the Fluid Power Handbook & Directory section of our web site, located at www.hydraulicspneumatics.com

 